Need an execution contractor?
Concrete scanning and GPR in Dubai and across the UAE.
This article explains the planning question. For scope review, method selection and a site-specific technical proposal, continue to Arasar's primary service page.
Match the record to the actual opening
Start with identification: project, level, room or grid reference, surveyed element and opening ID. Check the drawing revision and survey date. An image without these references may be difficult to relate to the physical workface, especially where many similar openings are proposed.
Confirm the extent of the surveyed area rather than assuming the report covers the entire room or structure. If a proposed opening was relocated or enlarged, ask whether the recorded investigation still covers the new requirement. A document title alone does not establish that coverage.
Distinguish the types of handover information
Hilti’s detection documentation distinguishes on-site visual outputs from exported information used for further analysis and reporting. Agree the output needed by your project instead of assuming that “3D scanning” always includes the same deliverables. The following is a completeness checklist, not a universal reporting standard.
| Record | Question for the survey team | Why it matters |
|---|---|---|
| Area and references | Where exactly was the investigation performed? | Connects the record to the opening and drawing |
| Site markings | What does each mark mean and where is the legend? | Avoids assumptions based only on colour |
| Annotated output | Which findings correspond to which location? | Makes the handover usable by the receiving team |
| Depth information | From which surface and with what limitations? | Avoids confusing cover, object depth and thickness |
| Uncertainty | Which areas or questions remain unresolved? | Separates evidence from assumptions |
| Decision ownership | Who reviews findings against the proposed work? | Keeps surveying distinct from permission to cut |
Ask what a depth value actually represents
A number may refer to a detected object below the scanned surface, an estimated element thickness or a setting used during data collection. Ask the survey specialist to explain the reference and meaning. Do not treat all depth values as equivalent or assume a displayed number is a guarantee of safe remaining clearance.
When concrete thickness is the project question, it should be stated in the survey scope and addressed in the findings with the applicable limitations. If the report does not resolve it, record the unanswered question for the responsible team. A generic equipment range does not answer a particular slab-thickness enquiry.
Keep uncertain areas visible in the decision record
A useful report can include uncertainty. Request a clear distinction between an interpreted finding, an area not investigated and a result that requires further review. Silence on a report should not be converted into a claim that there are no concealed objects.
Compare the report’s scope with the drawings and site references. If information conflicts, ask the responsible parties to resolve the discrepancy before treating the opening as released. The required next step depends on the actual question; this guide does not prescribe additional testing or structural conclusions.
Record changes between survey and execution
The handover should remain traceable when a drawing revision, opening position or work area changes. Keep the original record and the clarification together rather than relying on an informal verbal instruction. Identify which team member receives and resolves the change.
For repeated openings, use the same IDs in the bore schedule and survey records. This reduces ambiguity about which location a clarification concerns. Where the receiving contractor did not commission the scan, confirm that the complete report and its limitations have been shared.
Request the records required for the next trade
Tell the survey provider whether the next step is core drilling, saw cutting or another investigation. Define the drawing format, location references and evidence the receiving team requires before commissioning the work. Include those deliverables in the quotation comparison.
For Arasar concrete scanning enquiries, provide the proposed work area and the reporting requirement together. Our service page covers the survey discussion; the related drilling and cutting pages cover execution after the necessary project review.
Frequently asked questions
01Does a 3D scanning image authorise concrete cutting?
No. It is survey information. The responsible team must consider it with the design, limitations and required approvals.
02Is a detected object depth the same as slab thickness?
Not necessarily. Ask what the value refers to, its reference surface and its limitations. Thickness needs to be addressed as a specific survey objective.
03Should every scanning contractor use the same marking colours?
Do not assume a universal colour convention. Obtain the legend and explanation for the actual survey and make them available to the receiving team.
04What if an opening changes after scanning?
Ask whether the new location and extent are covered by the existing investigation. Keep the drawing revision and the resulting clarification with the project record.
Technical and regulatory references
Requirements remain project- and authority-specific. These public sources support the technical or regulatory points used in this guide.
Project note
Guidance is the starting point. The site determines the method.
Every structure, access route and operating environment is different. Final engineering, approvals and controls should be based on verified project information and a site-specific assessment.